add sabagen

This commit is contained in:
Seiji Nakamura
2025-05-12 15:46:04 +09:00
parent ccf21dac76
commit 33284ef5ac
186 changed files with 17145 additions and 0 deletions

View File

@@ -0,0 +1,18 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F3 59[1.2]-110[1.3], 288[3.7]
##
ts: 59+1.2/10 110+1.3/10 288+3.7/10
0:00 ts

View File

@@ -0,0 +1,19 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F03 50[1.2] 100[1.3] 288[3.6]
##
ts: 50+1.2/10 100+1.3/10 288+3.6/10
0:00 ts

View File

@@ -0,0 +1,20 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F10 100[1.5], 200[4.0], 250[4.0], 300[4.0]
##
## "Brain awake, body asleep"
##
ts: 100+1.5/10 200+4.0/10 250+4.0/10 300+4.0/10
0:00 ts

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F10 100[1.5] 200[4.0] 250[4.0] 300[4.0]
##
## "Brain awake, body asleep"
##
ts: 100+1.5/10 200+4.0/10 250+4.0/10 300+4.0/10
0:00 ts

View File

@@ -0,0 +1,20 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F12 100[1.5], 200[4.0], 250[4.0], 300[4.0], 400[10.0], 500[10.1], 600[4.8]
##
## "Expanded consciousness -- in the mood to head out and explore"
##
ts: 100+1.5/10 200+4.0/10 250+4.0/10 300+4.0/10 400+10.0/10 500+10.1/10 600+4.8/10
0:00 ts

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F12 50[0.25] 100[1.5] 200[4.0] 250[4.0] 300[4.0] 400[10.0] 500[10.1] 600[4.8]
##
## "Expanded consciousness -- in the mood to head out and explore"
##
ts: 50+0.25/10 100+1.5/10 200+4.0/10 250+4.0/10 300+4.0/10 400+10.0/10 500+10.1/10 600+4.8/10
0:00 ts

View File

@@ -0,0 +1,20 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F15 100[1.5], 200[4.0], 250[4.0], 300[4.0], 500[7.05], 630[7.1], 750[7.0]
##
## "No time -- 3 hours seems like 2 minutes"
##
ts: 100+1.5/10 200+4.0/10 250+4.0/10 300+4.0/10 500+7.05/10 630+7.1/10 750+7.0/10
0:00 ts

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F15 100[1.5] 200[4.0] 250[4.0] 300[4.0] 500[7.05] 630[7.0] 750[7.0]
##
## "No time -- 3 hours seems like 2 minutes"
##
ts: 100+1.5/10 200+4.0/10 250+4.0/10 300+4.0/10 500+7.05/10 630+7.0/10 750+7.0/10
0:00 ts

View File

@@ -0,0 +1,22 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F21 200[4.0], 250[4.0], 300[4.0], 600[16.2], 750[15.9], 900[16.2]
## F22 Same as F21
##
## "Alternate energy systems, bridge into worlds with non-human
## entities." (Focus 21)
##
ts: 200+4.0/10 250+4.0/10 300+4.0/10 600+16.2/10 750+15.9/10 900+16.2/10
0:00 ts

View File

@@ -0,0 +1,22 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F21 200[4.0] 250[4.0] 300[4.0] 600[16.2] 750[16.2] 900[16.2]
##
## "Alternate energy systems, bridge into worlds with non-human
## entities."
##
ts: 200+4.0/10 250+4.0/10 300+4.0/10 600+16.2/10 750+16.2/10 900+16.2/10
0:00 ts

View File

@@ -0,0 +1,23 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## Sometimes F21 is as follows:
## F21 200[4.0] 250[5.4] 300[5.4] 600[16.2] 750[16.2] 900[16.2]
##
## "Alternate energy systems, bridge into worlds with non-human
## entities."
##
ts: 200+4.0/10 250+5.4/10 300+5.4/10 600+16.2/10 750+16.2/10 900+16.2/10
0:00 ts

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F22 200[4.0] 250[4.0] 300[4.0] 600[16.2] 750[16.2] 900[16.2] (same as F21)
##
## "Place where people with loose, chaotic thoughts go after death."
##
ts: 200+4.0/10 250+4.0/10 300+4.0/10 600+16.2/10 750+16.2/10 900+16.2/10
0:00 ts

View File

@@ -0,0 +1,18 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F23 400[3.9], 503[4.0], 600[4.0], 750[3.9], 900[4.0]
##
ts: 400+3.9/10 503+4.0/10 600+4.0/10 750+3.9/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,19 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F23 400[3.9] 503[4.0] 600[4.0] 750[3.9] 900[4.0]
##
ts: 400+3.9/10 503+4.0/10 600+4.0/10 750+3.9/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F24 50[0.75], 400[3.9], 503[4.0], 600[4.0], 750[4.0], 900[4.0]
##
## "Belief system territories -- place where dogmatically inclined
## people go after death."
##
ts: 50+0.75/10 400+3.9/10 503+4.0/10 600+4.0/10 750+4.0/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,22 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F24 50[0.75] 200[1.5] 400[3.9] 503[4.0] 600[4.0] 750[4.0] 900[4.0]
##
## "Belief system territories -- place where dogmatically inclined
## people go after death."
##
ts: 50+0.75/10 200+1.5/10 400+3.9/10 503+4.0/10 600+4.0/10 750+4.0/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,18 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F25 503[4.0], 600[4.0], 750[4.0], 900[4.0]
##
ts: 503+4.0/10 600+4.0/10 750+4.0/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,19 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "focus.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be exactly the same
## as the Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience. Despite that, these tone-sets (or Focus levels)
## may be useful for experimenters to base their own tone-sets on.
##
## F26 400[3.9], 503[4.2], 600[4.0], 750[4.0], 900[4.0]
## F27 Same as F26
##
ts: 400+3.9/10 503+4.2/10 600+4.0/10 750+4.0/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,19 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F26 400[3.9] 503[4.2] 600[4.0] 750[4.0] 900[4.0]
##
ts: 400+3.9/10 503+4.2/10 600+4.0/10 750+4.0/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,22 @@
##
## Please note: These tone-sets are based on data from a document
## received from an anonymous source. See "focus.txt" for details.
## The data is almost identical to the USENET-released data that
## appears in the *-a.sbg files. It is included here though
## because in a few tone-sets, extra tones were included, which may
## be interesting or useful to certain experimenters. Also
## although the frequencies were measured, again the relative
## amplitudes of the tones were not, so the results are not likely
## to be exactly the same as the Monroe Institute tapes. Also I
## believe that the Monroe Institute uses a guiding voice that
## leads the subject through the experience.
##
## F27 50[0.80] 400[4.0] 503[4.2] 600[4.0] 750[4.0] 900[4.0]
##
## "The park -- a way-station, a place of high creativity, a
## stepping stone into areas beyond"
##
ts: 50+0.80/10 400+4.0/10 503+4.2/10 600+4.0/10 750+4.0/10 900+4.0/10
0:00 ts

View File

@@ -0,0 +1,7 @@
## "Catnapper", posted to sbagen-users by Takeshi Sone, Wed, 11 Jul
## 2007. This is intended to have an effect something like the
## similarly-named Monroe Institute product.
ts: 50.25+0.5/17 100+1.5/33 120/1.7 240/0.3
0:00 ts

View File

@@ -0,0 +1,7 @@
## "Concentration", posted to sbagen-users by Takeshi Sone, Wed, 11
## Jul 2007. This is intended to have an effect something like the
## similarly-named Monroe Institute product.
ts: 120/4.7 200+4/30 220.8/0.8 240.3/1.3 250+16/25 650+24/0.4 700+36/0.3
0:00 ts

View File

@@ -0,0 +1,9 @@
## Posted by Takeshi Sone to the sbagen-users mailing list on Thu, 14
## Jun 2007. This is intended to have an effect similar to a part of
## the Gateway Experience CD from the Monroe Institute.
##
## ts1-focus03.sbg
focus03: spin:300+0.1/25 100.1+1.5/5 120+120/0.4 120/1 150.3-4.1/5 200.3-3.9/5 240/0.3 300/0.1 502.5+3.5/0.5
0:00 focus03

View File

@@ -0,0 +1,9 @@
## Posted by Takeshi Sone to the sbagen-users mailing list on Thu, 14
## Jun 2007. This is intended to have an effect similar to a part of
## the Gateway Experience CD from the Monroe Institute.
##
## ts1-focus10.sbg
focus10: spin:300+0.1/25 87.75-1.5/2.3 120/1.3 177+4/4.4 264+4/3.1
0:00 focus10

View File

@@ -0,0 +1,9 @@
## Posted by Takeshi Sone to the sbagen-users mailing list on Thu, 14
## Jun 2007. This is intended to have an effect similar to a part of
## the Gateway Experience CD from the Monroe Institute.
##
## ts1-focus12.sbg
focus12: spin:300+0.1/25 50.25+0.5/14.2 100+1.5/4.4 120/1.2 200+4/1.4 240/0.3 250+4/0.8 300+4/0.5 400+10/0.5 500+10/0.5 600+10/0.4
0:00 focus12

View File

@@ -0,0 +1,9 @@
## Posted by Takeshi Sone to the sbagen-users mailing list on Thu, 14
## Jun 2007. This is intended to have an effect similar to a part of
## the Gateway Experience CD from the Monroe Institute.
##
## ts1-focus15.sbg
focus15: spin:300+0.1/25 120/1.5 202.15-4.3/0.7 240/0.3 250/0.5 254.25-0.5/0.4 302.4-4.8/0.9 507.55+7.3/0.6 606.6-7.3/0.6 803.65-7.3/0.6
0:00 focus15

View File

@@ -0,0 +1,9 @@
## Posted by Takeshi Sone to the sbagen-users mailing list on Thu, 14
## Jun 2007. This is intended to have an effect similar to a part of
## the Gateway Experience CD from the Monroe Institute.
##
## ts1-focus21.sbg
focus21: spin:300+0.1/25 120/1.7 200+4/4.6 240/0.3 250+4/2.7 300+4/1.7 600+16/1.3 755+16/0.7 900+16/0.4
0:00 focus21

View File

@@ -0,0 +1,9 @@
## Posted by Takeshi Sone to the sbagen-users mailing list on Thu, 14
## Jun 2007. This is intended to have an effect similar to a part of
## the Gateway Experience CD from the Monroe Institute.
##
## ts1-homing.sbg
homing: 475+16/9 599.5+17/3 599.5+63/3
0:00 homing

View File

@@ -0,0 +1,9 @@
## Posted by Takeshi Sone to the sbagen-users mailing list on Thu, 14
## Jun 2007. This is intended to have an effect similar to a part of
## the Gateway Experience CD from the Monroe Institute.
##
## ts1-intro.sbg
intro: spin:300+0.1/25 50.25-0.5/8 100-1.5/16 120/1.6 240/0.3
0:00 intro

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 1 - Orientation (Focus 3)
## Hemisync, Energy Conversion Box, Gateway Affirmation, Resonant Tuning
##
## l/r 300/304 plus 100 Hz and 500 Hz carriers without recognizeable Delta
##
ts: 100+0/10 302+4/10 500+0/10
0:00 ts

View File

@@ -0,0 +1,22 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 2 - Intro Focus 10
##
## Focus 10, Ten Point Relaxation
##
## 100[4.0], 300[4.0], 500[4.0]
##
ts: 100+4.0/10 300+4.0/10 500+4.0/10
0:00 ts

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 4 - Release and Recharge (Focus 10)
## Process of Energy Conversion - Daily Exercise!
##
## l/r 100/104, 414/410, 504/500
##
ts: 102+4/10 412-4/10 502-4/10
0:00 ts

View File

@@ -0,0 +1,21 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 5 - Exploration Sleep (Focus 10)
## Remembering who and what you are, Rolling out, Floating upwards
##
## l/r 100/104, 300/304, 496/500
##
ts: 102+4/10 302+4/10 498+4/10
0:00 ts

View File

@@ -0,0 +1,20 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 6 - Focus 10 Free Flow for your own purpose
##
## l/r 100/104, 300/304, 500/504
##
ts: 102+4/10 302+4/10 502+4/10
0:00 ts

View File

@@ -0,0 +1,20 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 6 - Focus 10 Free Flow for your own purpose
##
## C1: 308/322, 500/515
##
ts: 315+14/10 507.5+15/10
0:00 ts

View File

@@ -0,0 +1,20 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 1 - Intro Focus 12
##
## l/r 51/51.75, 98.75/101; Delta-Frq: 0.75 + 2.25 Hz
##
ts: 51.375+0.75/10 99.875+2.25/10
0:00 ts

View File

@@ -0,0 +1,19 @@
##
## Please note: These tone-sets are based on data from a document
## that appeared on USENET, from someone who appears to have
## measured the frequencies used on some of the Monroe Institute
## tapes. See "wave.txt" for more details. Although the
## frequencies were measured, the relative amplitudes of the tones
## were not, so the results are not likely to be identical to the
## Monroe Institute tapes. Also I believe that the Monroe
## Institute uses a guiding voice that leads the subject through
## the experience.
##
## Tape 2 - Problem Solving (Focus 12)
##
## l/r 99.5/101, 202.7/204.2
##
ts: 100.25+1.5/10 203.45+1.5/10
0:00 ts